Abstract
Aim: The aim of this study was to evaluate the rates and types of drug prescription and administration errors in one pediatric nephrology ward, comparing two dispensing schemes : the first one defined as handwritten prescription plus ward stock distribution system (WSDS), and the second one as computerized prescription plus unit dose drug dispensing system (UDDDS). Method: Data were collected over an 8‐week period, from 1 February to 31 March 1999. Two fifth‐year pharmacy students photocopied prescription and administration documents on the ward each day, under the supervision of a senior pharmacist. The medical record analysis was used to compare the prescription with the administration report. Prescribing and administration medication errors were classified according to the American Society of Health‐System Pharmacists.Results: Prescribing errors: overall, for both dispensing schemes, a total of 511 prescriptions, resulting in 4532 prescribed drugs (an average of 9 drugs per prescription) were prescribed. The total prescription error rate was 20.7% (937 of 4532), resulting in 1.9 errors per patient per day. The computerized prescription error rate was 10.6% (419 of 3943), the handwritten prescription error rate was 87.9% (518 of 589). This difference was very significant (P < 0.0001).Administration errors: the total opportunity of administration errors was 4589 (sum of administered and omitted drugs). The total administration error rate was 23.5% (1077 of 4589) including wrong administration time, and 11.7% (538 of 4589) excluding administration time. The administration error rate, including administration associated with time errors, was only 22.5% (888 of 3943) for computerized prescription + UDDDS, compared with 29.3% (189 of 646) for handwritten prescriptions plus WSDS (P < 0.001). Excluding administration associated with time errors, the administration error rates were 9.7% and 24.3%, respectively (P < 0.0001). Conclusion: The drug prescription and administration error rates were significantly decreased using computerized prescription plus UDDDS as compared with handwritten prescription plus WSDS in a pediatric unit (even with potential biases taken into account).
Similar content being viewed by others
References
ASHP Reports. Draft guidelines on preventable medication errors. Am J Pharm 1992; 49: 640–8.
ASHP Reports. Draft guidelines on preventable medication errors in hospitals. Am J Hosp Pharm 1993; 50: 305–14.
Barker KN, Allan EL. Research on drug-use-system errors. Am J Health Syst Pharm 1995; 52: 400–3.
Schmitt E. Le risque médicamenteux nosocomial. Paris: Masson, 1999.
Barker KN, McConnwell WE. The problem of detecting errors in hospitals. Am J Hosp Pharm 1962; 19: 361–9.
Hynniman CE, Conrad WF, Urch WA, Rudnick BR, Parker PF. A comparison of the medication errors under the unit-dose and traditional drug distribution system in four hospitals. Am J Hosp Pharm 1970; 27: 802–14.
Fontan JE, Arnaud P, Aujard Y, Boisson A, Léglise J, Brion F. De la prescription à la gestion: apports de l'informatique hospitalière à l'assurance qualité pharmaceutique. J Pharm Clin 1995; 14: 280–8.
Barker KN, Kimbrough WW, Heller WM. The medication error problem in hospitals: I - the detection and the use of errors as a measurement of medication system. Hosp Formulary 1966; 1: 29–34.
Allan EL, Barker KN. Fundamentals of medication error research. Am J Hosp Pharm 1990; 47: 555–71.
ASHP Reports. Suggested definitions and relationships among medication misadventures, medication errors, adverse drug events, and adverse drug reactions. Am J Health Syst Pharm 1998; 55: 165–6.
McNally KM, Page MA, Sunderland BV. Failure-mode and effects analysis in improving a drug distribution system. Am J Health Syst Pharm 1997; 54: 171–7.
Flynn E, Barker KN, Pepper GA, Bates DW, Mikeal R. Comparison of methods for detecting medication errors in 36 hospitals and skilled-nursing facilities. Am J Health Syst Pharm 2002; 59: 436–45.
Bontemps H, Fauconnier J, Bosson JL, Brilloit C, François P, Calop J. Evaluation de la qualité de la prescription des médicaments dans un CHU. J Pharm Clin 1997; 16: 49–53.
Bates DW, Leape LC, Cullen DJ, Laird N, Petersen LA, Teich JM et al. Effect of computerized physician order entry and a team intervention on prevention of serious medication errors. J Am Med Assoc 1998; 2080: 1311–6.
Schneider MP, Cotting J, Pannatier A. Evaluation of nurses' errors associated with the preparation and administration of medication in a pediatric intensive care unit. Pharm World Sci 1998; 20(4): 178–82.
Tisdale JE. Justifying a pediatric critical-care satellite pharmacy by medication error reporting. Am J Hosp Pharm 1986; 43: 368–71.
Perlstein PH, Callison C, White M, Barnes B, Edwards NK. Errors in drug computations during newborn intensive care. Am J Dis Child 1979; 133: 376–9.
Ross LM, Wallace J, Paton JY. Medication errors in a paediatric teaching hospital in the UK: five years operational experience. BMJ 2000; 83: 492–7.
Kaushal R, Bates DW, Landrigan C, Mc Kenna K, Clapp MD, Frederico F, Goldman DA. Medication errors and adverse drug events in pediatrics. J Am Med Assoc 2001; 2085: 2114–20.
Dean BS, Barber ND. A validated, reliable method of scoring the severity of medication errors. Am J Health Syst Pharm 1999; 56: 57–62.
Bates DW, Boyle DL, Van Der Vliet MB. Relationship between medication errors and adverse drug events. J Gen Int Med 1995; 10: 199–205.
ASHP Reports. Guidelines for providing pediatric pharmaceutical services in organized health care systems. Am J Hosp Pharm 1994; 51: 1690–2.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Fontan, J.E., Maneglier, V., Nguyen, V. et al. Medication errors in hospital: computerized unit dose drug dispensing system versus ward stock distribution system. Pharm World Sci 25, 112–117 (2003). https://doi.org/10.1023/A:1024053514359
Issue Date: